ABB Error 37281 — Wrong feedback from sensor for YV10 bell cup brake air, after change state of YV10 A1BrakeSaf
Error / Erreur🇫🇷 Wrong feedback from sensor for YV10 bell cup brake air, after change state of YV10 A1BrakeSaf
ABB — CATALOGUE PRODUCTION
ABB 37281 (“Wrong feedback from sensor for YV10 bell cup brake air, after change state of YV10 A1BrakeSaf”): Wrong feedback from sensor for YV10 bell cup brake air, after change state of YV10 A1BrakeSaf — ABB robot hardware event on the Wrong feedback from sensor for YV10 bell cup brake air, after change state of YV10 A1BrakeSaf (IRC5).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Wrong feedback from sensor for YV10 bell cup brake air, after change state of YV10 A1BrakeSaf — ABB robot hardware event on the Wrong feedback from sensor for YV10 bell cup brake air, after change state of YV10 A1BrakeSaf (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
A fault is observed on activation of brake air valve. Divergence reported on feedback. The enable chain will be opened if valve did not deactivate. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.
What to check · Que vérifier
- Inspect the Wrong feedback from sensor for YV10 bell cup brake air, after change state of YV10 A1BrakeSaf, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- Check HMI and system status.
- Check cables and connections.
- Check valve YV10 and sensor SP5.
Frequently asked · Questions fréquentes
- What does ABB error 37281 mean?
- ABB 37281 (“Wrong feedback from sensor for YV10 bell cup brake air, after change state of YV10 A1BrakeSaf”): Wrong feedback from sensor for YV10 bell cup brake air, after change state of YV10 A1BrakeSaf — ABB robot hardware event on the Wrong feedback from sensor for YV10 bell cup brake air, after change state of…
- How do you troubleshoot ABB error 37281?
- Inspect the Wrong feedback from sensor for YV10 bell cup brake air, after change state of YV10 A1BrakeSaf, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →