What it means
DC link input voltage too low; loss of a phase or fault in the rectifier/DC link chain. Incorrect insertion of the DC busbar or the bleeder resistor wiring can also cause the event.
What to check
- LOTO before any work.
- Check the rectifier three-phase supply, fuses, contactors, DC busbar insertion and bleeder resistor wiring.
- If the upstream supplies are correct, isolate the rectifier and wiring.
- Note: Functional equivalent of the IRC5 DC link undervoltage faults; historically an S4C+ code.
Part to check / replace
ABB 38600 points to the hardware below — start here before ordering.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.