ABB Error 38665 — Motor / cable motor / Drive fault
ErrorABB 38665 (“Motor / cable motor / Drive fault”): Short circuit detected on the motor or cable of an axis. Likely part: Moteur / Câble moteur / Drive (motor / cable motor / Drive).
Updated 2026-10-22 · LogrobotLM reference
What it means
Short circuit detected on the motor or cable of an axis.
What to check
- LOTO.
- Inspect cable, connectors and motor; check the insulation and the windings.
- If wiring and motor are sound, isolate the Drive/power section.
- Do not repeatedly reset a hard fault.
- Note: Well-documented S4C+ hardware fault; other interventions were resolved by repairing the cable or replacing the Drive module.
Part to check / replace
ABB 38665 points to the hardware below — start here before ordering.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.
Related codes
Same hardware involved
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →