ABB Error 39401 — Torque Current Reference Error
Error / Erreur🇫🇷 Torque Current Reference Error
ABB — CATALOGUE PRODUCTION
ABB 39401 (“Torque Current Reference Error”): Torque Current Reference Error — ABB robot hardware event on the Torque Current Reference Error (IRC5).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Torque Current Reference Error — ABB robot hardware event on the Torque Current Reference Error (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
The torque-current reference is increasing too quickly for joint arg, connected to drive module arg . Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.
What to check · Que vérifier
- Inspect the Torque Current Reference Error, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- probable : The resolver feedback may be poor or the speed loop gain may be badly adjusted.
- Check the resolver cable and the resolver grounding for this joint.
- If this joint is an additional axis, then check that the motor data in the configuration file is correct.
- The configuration data is described in Technical reference manual - System parameters.
- Reduce the gain of the speed loop.
Frequently asked · Questions fréquentes
- What does ABB error 39401 mean?
- ABB 39401 (“Torque Current Reference Error”): Torque Current Reference Error — ABB robot hardware event on the Torque Current Reference Error (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 39401?
- Inspect the Torque Current Reference Error, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →