ABB Error 39404 — Torque Loop Overcurrent
Error / Erreur🇫🇷 Torque Loop Overcurrent
ABB — CATALOGUE PRODUCTION
ABB 39404 (“Torque Loop Overcurrent”): Torque Loop Overcurrent — ABB robot hardware event on the Torque Loop Overcurrent (IRC5).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Torque Loop Overcurrent — ABB robot hardware event on the Torque Loop Overcurrent (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
The field-current controller detected too high current for joint arg, connected to drive module arg . Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.
What to check · Que vérifier
- Inspect the Torque Loop Overcurrent, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- probable : The motor data in the configuration files may be wrong.
- Check that the motor data in the configuration file is correct for this joint.
- The configuration data is described in Technical reference manual - System parameters.
- Check that no DC bus errors are present in the event log.
- Check that the incoming mains voltage is within the specification.
Frequently asked · Questions fréquentes
- What does ABB error 39404 mean?
- ABB 39404 (“Torque Loop Overcurrent”): Torque Loop Overcurrent — ABB robot hardware event on the Torque Loop Overcurrent (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 39404?
- Inspect the Torque Loop Overcurrent, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →