LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 39404Torque Loop Overcurrent

Error / Erreur

🇫🇷 Torque Loop Overcurrent

ABB — CATALOGUE PRODUCTION

ABB 39404 (“Torque Loop Overcurrent”): Torque Loop Overcurrent — ABB robot hardware event on the Torque Loop Overcurrent (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Torque Loop Overcurrent — ABB robot hardware event on the Torque Loop Overcurrent (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

The field-current controller detected too high current for joint arg, connected to drive module arg . Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Torque Loop Overcurrent, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : The motor data in the configuration files may be wrong.
  • Check that the motor data in the configuration file is correct for this joint.
  • The configuration data is described in Technical reference manual - System parameters.
  • Check that no DC bus errors are present in the event log.
  • Check that the incoming mains voltage is within the specification.

Frequently asked · Questions fréquentes

What does ABB error 39404 mean?
ABB 39404 (“Torque Loop Overcurrent”): Torque Loop Overcurrent — ABB robot hardware event on the Torque Loop Overcurrent (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 39404?
Inspect the Torque Loop Overcurrent, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →