LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 39440Open circuit in bleeder resistor circuit

Error / Erreur

🇫🇷 Open circuit in bleeder resistor circuit

ABB — CATALOGUE PRODUCTION

ABB 39440 (“Open circuit in bleeder resistor circuit”): Open circuit in bleeder resistor circuit — ABB robot hardware event on the Open circuit in bleeder resistor resistor circuit (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Open circuit in bleeder resistor circuit — ABB robot hardware event on the Open circuit in bleeder resistor resistor circuit (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

The bleeder resistor connected to the rectifier on drive link arg, drive module arg, is an open circuit. No operation will be possible until after correcting the fault. The system goes to status SYS HALT. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Open circuit in bleeder resistor resistor circuit, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : This may be caused by a faulty bleeder resistor cable or bleeder resistor.
  • - 1) Make sure the bleeder resistor cable is correctly connected to the rectifier unit.
  • - 2) Make sure the cable and resistor is working correctly by measuring their resistance respectively.
  • Disconnect before measuring.
  • - 3) Replace any faulty component.

Frequently asked · Questions fréquentes

What does ABB error 39440 mean?
ABB 39440 (“Open circuit in bleeder resistor circuit”): Open circuit in bleeder resistor circuit — ABB robot hardware event on the Open circuit in bleeder resistor resistor circuit (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains…
How do you troubleshoot ABB error 39440?
Inspect the Open circuit in bleeder resistor resistor circuit, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →