LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 39442Bleeder Resistance Too Low

Error / Erreur

🇫🇷 Bleeder Resistance Too Low

ABB — CATALOGUE PRODUCTION

ABB 39442 (“Bleeder Resistance Too Low”): Bleeder Resistance Too Low — ABB robot hardware event on the bleeder resistor Resistance Too Low (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Bleeder Resistance Too Low — ABB robot hardware event on the bleeder resistor Resistance Too Low (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

The bleeder resistance is too low for the rectifier on drive communication link arg, drive module arg . No operation will be possible until after correcting the fault. The system goes to status SYS HALT. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the bleeder resistor Resistance Too Low, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : The bleeders may have the wrong resistance value or one of the bleeders may have failed, causing a short circuit.
  • Check the bleeder resistors to see that they are the correct resistance value for this drive module configuration.
  • Check that none of the resistors have failed.
  • The configuration data is described in Technical reference manual - System parameters.

Frequently asked · Questions fréquentes

What does ABB error 39442 mean?
ABB 39442 (“Bleeder Resistance Too Low”): Bleeder Resistance Too Low — ABB robot hardware event on the bleeder resistor Resistance Too Low (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 39442?
Inspect the bleeder resistor Resistance Too Low, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →