ABB Error 39484 — Run chain open in motor on state
Error / Erreur🇫🇷 Run chain open in motor on state
ABB — CATALOGUE PRODUCTION
ABB 39484 (“Run chain open in motor on state”): Run chain open in motor on state — ABB robot hardware event on the Run chain open in motor on state (IRC5).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Run chain open in motor on state — ABB robot hardware event on the Run chain open in motor on state (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
Run chain arg is open when system is in motor on state. The problem occurred in drive system arg . System goes to SYS\_HALT. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.
What to check · Que vérifier
- Inspect the Run chain open in motor on state, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- probable : - 1) The cable between the panel board and the contactor interface board is unpluged or damaged.
- - 2) The contactor for this run chain in the drive module may be stuck due to mecanical problem in contactor itself.
- - 3) The help contactor on the contactor can suffer from bad galvanic behavour or faulty cable to contactor interface board.
- - 1) Check the cable between the panel board and the contactor interface board.
- - 2) If the contactor is stuck in one position, replace the contactor.
Frequently asked · Questions fréquentes
- What does ABB error 39484 mean?
- ABB 39484 (“Run chain open in motor on state”): Run chain open in motor on state — ABB robot hardware event on the Run chain open in motor on state (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 39484?
- Inspect the Run chain open in motor on state, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →