ABB Error 39527 — Axis computer not found in single Multi Move system
Error / Erreur🇫🇷 Axis computer not found in single Multi Move system
ABB — CATALOGUE PRODUCTION
ABB 39527 (“Axis computer not found in single Multi Move system”): Axis computer not found in single Multi Move system — ABB robot hardware event on the Axis computer not found in single Multi Move system (IRC5).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Axis computer not found in single Multi Move system — ABB robot hardware event on the Axis computer not found in single Multi Move system (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
The axis computer in drive module arg is not connected to the main computer. The system goes to system failure state. No operation will be possible until the fault has been corrected. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.
What to check · Que vérifier
- Inspect the Axis computer not found in single Multi Move system, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- probable : This may be due to a cable break, badly connected connectors, missing axis computer switch, or loss of power supply.
- Make sure that the cable from the main computer through the switch to the axis computer is not damaged and that all connectors are correctly connected.
- Make sure that the power supply to the axis computer is working correctly.
- Restart the controller.
Frequently asked · Questions fréquentes
- What does ABB error 39527 mean?
- ABB 39527 (“Axis computer not found in single Multi Move system”): Axis computer not found in single Multi Move system — ABB robot hardware event on the Axis computer not found in single Multi Move system (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own…
- How do you troubleshoot ABB error 39527?
- Inspect the Axis computer not found in single Multi Move system, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →