LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 39605Power Unit 24V supply error

Error / Erreur

🇫🇷 Power Unit 24V supply error

ABB — CATALOGUE PRODUCTION

ABB 39605 (“Power Unit 24V supply error”): Power Unit 24V supply error — ABB robot hardware event on the Power Unit 24V supply error (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Power Unit 24V supply error — ABB robot hardware event on the Power Unit 24V supply error (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

The Power Unit with unit position arg has detected problem with the logic power. No operation will be possible until the fault is corrected. The system goes to Motors Off state with zero torque. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Power Unit 24V supply error, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : The 24V logic supply to the drive is temporary or constantly lost.
  • - 1 Check the event log for power supply unit error messages.

Frequently asked · Questions fréquentes

What does ABB error 39605 mean?
ABB 39605 (“Power Unit 24V supply error”): Power Unit 24V supply error — ABB robot hardware event on the Power Unit 24V supply error (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 39605?
Inspect the Power Unit 24V supply error, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →