ABB Error 39610 — Short circuit in bleeder resistor circuit
Error / Erreur🇫🇷 Short circuit in bleeder resistor circuit
ABB — CATALOGUE PRODUCTION
ABB 39610 (“Short circuit in bleeder resistor circuit”): Short circuit in bleeder resistor circuit — ABB robot hardware event on the Short circuit in bleeder resistor resistor circuit (IRC5).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Short circuit in bleeder resistor circuit — ABB robot hardware event on the Short circuit in bleeder resistor resistor circuit (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
The bleeder resistor connected to the Power Unit at unit position arg is indicating a short circuit. No operation will be possible until the fault is corrected. The system goes to Motors Off state. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.
What to check · Que vérifier
- Inspect the Short circuit in bleeder resistor resistor circuit, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- probable : This may be caused by a faulty bleeder resistor cable or a faulty bleeder resistor.
- Make sure the bleeder resistor cable is correctly connected to the rectifier unit.
- Disconnect the bleeder and check the cable and measure the bleeder resistance.
- Check for bleeder short circuit against ground.
Frequently asked · Questions fréquentes
- What does ABB error 39610 mean?
- ABB 39610 (“Short circuit in bleeder resistor circuit”): Short circuit in bleeder resistor circuit — ABB robot hardware event on the Short circuit in bleeder resistor resistor circuit (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains…
- How do you troubleshoot ABB error 39610?
- Inspect the Short circuit in bleeder resistor resistor circuit, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →