ABB Error 39613Rectifier temperature error

Error / Erreur

🇫🇷 Rectifier temperature error

ABB — CATALOGUE PRODUCTION

ABB 39613 (“Rectifier temperature error”): Rectifier temperature error — ABB robot hardware event on the Rectifier temperature error (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Rectifier temperature error — ABB robot hardware event on the Rectifier temperature error (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

In Power Unit at unit position arg has reached a too high temperature level. No operation will be possible until the rectifier has cooled down. The system goes to Motors Off state. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Rectifier temperature error, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : - 1 The cooling fans may be faulty or the air flow may be obstructed.
  • - 2 The ambient temperature may be too high.
  • - 3 The system may be running with a too high torque for extended periods of time.
  • Verify that the fans are running and that the air flow is not obstructed.
  • Verify that the ambient temperature does not exceed the cabinet's temperature rating.

Frequently asked · Questions fréquentes

What does ABB error 39613 mean?
ABB 39613 (“Rectifier temperature error”): Rectifier temperature error — ABB robot hardware event on the Rectifier temperature error (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 39613?
Inspect the Rectifier temperature error, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →