LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 41480UnpackRawBytes Error

Error / Erreur

🇫🇷 UnpackRawBytes Error

ABB — CATALOGUE PRODUCTION

ABB 41480 (“UnpackRawBytes Error”): UnpackRawBytes Error — ABB robot hardware event on the UnpackRawBytes Error (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

UnpackRawBytes Error — ABB robot hardware event on the UnpackRawBytes Error (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

Task: arg . The number of bytes to unpack is too high, and has been reduced. Length: arg . Program ref: arg . The string has been filled with data, but only the valid amount. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the UnpackRawBytes Error, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : The value used in arg optional argument is too high.
  • Check the RAPID program.
  • Use function arg to get the current length of valid bytes in the rawbytes variable.

Frequently asked · Questions fréquentes

What does ABB error 41480 mean?
ABB 41480 (“UnpackRawBytes Error”): UnpackRawBytes Error — ABB robot hardware event on the UnpackRawBytes Error (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 41480?
Inspect the UnpackRawBytes Error, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →