LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 41613InitValue not within specified value range

Error / Erreur

🇫🇷 InitValue not within specified value range

ABB — CATALOGUE PRODUCTION

ABB 41613 (“InitValue not within specified value range”): InitValue not within specified value range — ABB robot hardware event on the InitValue not within specified value range (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

InitValue not within specified value range — ABB robot hardware event on the InitValue not within specified value range (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

Task: arg In function UINumEntry or UINumTune, the argument \InitValue is not specified within the range \MaxValue ... \MinValue. Program Ref. arg Not possible to continue the program execution. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the InitValue not within specified value range, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Change the argument \InitValue so it's inside the value range.
  • Recovery: arg

Frequently asked · Questions fréquentes

What does ABB error 41613 mean?
ABB 41613 (“InitValue not within specified value range”): InitValue not within specified value range — ABB robot hardware event on the InitValue not within specified value range (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains…
How do you troubleshoot ABB error 41613?
Inspect the InitValue not within specified value range, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →