ABB Error 41692RMQ Error - Not valid Slot

Error / Erreur

🇫🇷 RMQ Error - Not valid Slot

ABB — CATALOGUE PRODUCTION

ABB 41692 (“RMQ Error - Not valid Slot”): RMQ Error - Not valid Slot — ABB robot hardware event on the RMQ Error - Not valid Slot (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

RMQ Error - Not valid Slot — ABB robot hardware event on the RMQ Error - Not valid Slot (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

Task: arg The arg used is not valid. Program Ref. arg Communication with client with current rmqslot is no longer possible. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the RMQ Error - Not valid Slot, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : The reason is arg: - 1) The rmqslot has not been initialized.
  • - 2) The destination slot is not valid anymore.
  • This can happen if a remote client has disconnected from the controller.
  • - 3) Instruction RMQSendWait was restarted after a power fail.
  • When the instruction is restarted, the arg is set to 0.

Frequently asked · Questions fréquentes

What does ABB error 41692 mean?
ABB 41692 (“RMQ Error - Not valid Slot”): RMQ Error - Not valid Slot — ABB robot hardware event on the RMQ Error - Not valid Slot (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 41692?
Inspect the RMQ Error - Not valid Slot, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →