ABB Error 41726 — Ignored StopMoveReset actions for task
Error / Erreur🇫🇷 Ignored StopMoveReset actions for task
ABB — CATALOGUE PRODUCTION
ABB 41726 (“Ignored StopMoveReset actions for task”): Ignored StopMoveReset actions for task — ABB robot hardware event on the Ignored StopMoveReset actions for task (IRC5).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Ignored StopMoveReset actions for task — ABB robot hardware event on the Ignored StopMoveReset actions for task (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
Task: arg . The StopMoveReset instruction had no impact on the system. Program ref: arg . The StopMove was not reset. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.
What to check · Que vérifier
- Inspect the Ignored StopMoveReset actions for task, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- probable : - 1 The Motion task has not been stopped.
- - 2 The Motion task was stopped by another non-Motion task: .
- This time the cause was arg .
- Use the switch \AllMotionTasks in StopMoveReset if this instruction should reset a StopMove from another non-Motion task.
Frequently asked · Questions fréquentes
- What does ABB error 41726 mean?
- ABB 41726 (“Ignored StopMoveReset actions for task”): Ignored StopMoveReset actions for task — ABB robot hardware event on the Ignored StopMoveReset actions for task (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 41726?
- Inspect the Ignored StopMoveReset actions for task, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →