LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 41775Ongoing request towards camera

Error / Erreur

🇫🇷 Ongoing request towards camera

ABB — CATALOGUE PRODUCTION

ABB 41775 (“Ongoing request towards camera”): Ongoing request towards camera — ABB robot hardware event on the Ongoing request towards camera (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Ongoing request towards camera — ABB robot hardware event on the Ongoing request towards camera (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

Task: arg . It is not allowed to have several parallel requests towards a camera. Program ref: arg . The request was not performed. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Ongoing request towards camera, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : There are more than one request towards the camera named arg .
  • Wait for a while, and then try again.
  • If trying to access the same camera from different tasks, instruction WaitTestAndSet can be used to prevent access of the camera at the same time.
  • Recovery: arg .

Frequently asked · Questions fréquentes

What does ABB error 41775 mean?
ABB 41775 (“Ongoing request towards camera”): Ongoing request towards camera — ABB robot hardware event on the Ongoing request towards camera (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 41775?
Inspect the Ongoing request towards camera, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →