ABB Error 41822 — No data from the UdpUc device
Error / Erreur🇫🇷 No data from the UdpUc device
ABB — CATALOGUE PRODUCTION
ABB 41822 (“No data from the UdpUc device”): No data from the UdpUc device — ABB robot hardware event on the No data from the UdpUc device (IRC5).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
No data from the UdpUc device — ABB robot hardware event on the No data from the UdpUc device (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
Task: arg . No expected data packets have been received for the EGM instance arg during arg seconds. Rapid Ref: arg . The program execution is stopped immediately. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.
What to check · Que vérifier
- Inspect the No data from the UdpUc device, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- Check the connection between the controller and the UdpUc device "".
- Check that the UdpUc device "" is working properly.
- Increase the value () for \CommTimeout in EGMSetupUC.
- Recovery: ERR\_UDPUC\_COMM.
Frequently asked · Questions fréquentes
- What does ABB error 41822 mean?
- ABB 41822 (“No data from the UdpUc device”): No data from the UdpUc device — ABB robot hardware event on the No data from the UdpUc device (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 41822?
- Inspect the No data from the UdpUc device, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →