LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 41852Wrong signal value for signal arg

Error / Erreur

🇫🇷 Wrong signal value for signal arg

ABB — CATALOGUE PRODUCTION

ABB 41852 (“Wrong signal value for signal arg”): Wrong signal value for signal arg — ABB robot hardware event on the Wrong signal value for signal arg (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Wrong signal value for signal arg — ABB robot hardware event on the Wrong signal value for signal arg (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

It is not possible to set the I/O signal arg to value arg . The program execution is stopped immediately. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Wrong signal value for signal arg, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : The I/O signal arg is configured wrong, or the value that should be set is wrong.
  • The signal value that is used has been read from a persistent variable specified in one of the setup instructions used for Trigg defining conditions and actions for setting a digital, a group of digital, or an analog output signal at a fixed position.
  • The error is detected when the actual signal setting should be done.
  • Check the I/O configuration for I/O signal.
  • Check the value of the persistent variable that is used in arg for the setup instruction(s) for Trigg.

Frequently asked · Questions fréquentes

What does ABB error 41852 mean?
ABB 41852 (“Wrong signal value for signal arg”): Wrong signal value for signal arg — ABB robot hardware event on the Wrong signal value for signal arg (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 41852?
Inspect the Wrong signal value for signal arg, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →