ABB Error 41852 — Wrong signal value for signal arg
Error / Erreur🇫🇷 Wrong signal value for signal arg
ABB — CATALOGUE PRODUCTION
ABB 41852 (“Wrong signal value for signal arg”): Wrong signal value for signal arg — ABB robot hardware event on the Wrong signal value for signal arg (IRC5).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Wrong signal value for signal arg — ABB robot hardware event on the Wrong signal value for signal arg (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
It is not possible to set the I/O signal arg to value arg . The program execution is stopped immediately. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.
What to check · Que vérifier
- Inspect the Wrong signal value for signal arg, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- probable : The I/O signal arg is configured wrong, or the value that should be set is wrong.
- The signal value that is used has been read from a persistent variable specified in one of the setup instructions used for Trigg defining conditions and actions for setting a digital, a group of digital, or an analog output signal at a fixed position.
- The error is detected when the actual signal setting should be done.
- Check the I/O configuration for I/O signal.
- Check the value of the persistent variable that is used in arg for the setup instruction(s) for Trigg.
Frequently asked · Questions fréquentes
- What does ABB error 41852 mean?
- ABB 41852 (“Wrong signal value for signal arg”): Wrong signal value for signal arg — ABB robot hardware event on the Wrong signal value for signal arg (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 41852?
- Inspect the Wrong signal value for signal arg, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →