LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 41880AliasCamera Define Error

Error / Erreur

🇫🇷 AliasCamera Define Error

ABB — CATALOGUE PRODUCTION

ABB 41880 (“AliasCamera Define Error”): AliasCamera Define Error — ABB robot hardware event on the AliasCamera Define Error (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

AliasCamera Define Error — ABB robot hardware event on the AliasCamera Define Error (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

Task: arg . The camera in argument CameraName or FromCamera: arg , must be defined in the Communication configuration (SIO,cfg) and the camera in argument ToCamera: arg , must be declared in the RAPID program and not defined in the Communication configuration (SIO,cfg). Program ref: arg . Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the AliasCamera Define Error, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Check the Communication configuration and the RAPID program.
  • Recovery: arg .

Frequently asked · Questions fréquentes

What does ABB error 41880 mean?
ABB 41880 (“AliasCamera Define Error”): AliasCamera Define Error — ABB robot hardware event on the AliasCamera Define Error (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 41880?
Inspect the AliasCamera Define Error, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →