ABB Error 50022 — Too low DC-link voltage
Error / Erreur🇫🇷 Too low DC-link voltage
ABB — CATALOGUE PRODUCTION
ABB 50022 (“Too low DC-link voltage”): Too low DC-link voltage — ABB robot hardware event on the Too low DC-link voltage (IRC5).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Too low DC-link voltage — ABB robot hardware event on the Too low DC-link voltage (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
The drive units cannot detect the dc link voltage, or the voltage is too low. This can occur if the DC link bus bar is not correctly inserted or if the mains contactors do not close properly. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.
What to check · Que vérifier
- Inspect the Too low DC-link voltage, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- Check the DC bus bar is correctly inserted between the drive unit and the rectifier.
- Check that the motors on contactors are closed and that there is voltage on the side connected to the rectifier.
Frequently asked · Questions fréquentes
- What does ABB error 50022 mean?
- ABB 50022 (“Too low DC-link voltage”): Too low DC-link voltage — ABB robot hardware event on the Too low DC-link voltage (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 50022?
- Inspect the Too low DC-link voltage, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →