ABB Error 50124 — Zone converted to fine point
Error / Erreur🇫🇷 Zone converted to fine point
ABB — CATALOGUE PRODUCTION
ABB 50124 (“Zone converted to fine point”): Zone converted to fine point — ABB robot hardware event on the Zone converted to fine point (IRC5).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Zone converted to fine point — ABB robot hardware event on the Zone converted to fine point (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
Task: arg . Corner path executed as stop point because the calculated time margin for next segment is 0. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.
What to check · Que vérifier
- Inspect the Zone converted to fine point, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- - Reduce the number of instructions between consecutive move instructions.
- - Reduce speed, use wider spaced points, use /CONC option.
- - Increase system parameter 'Prefetch Time' in topic Motion and type Motion Planner.
- - If the stop comes at the first movement after a finepoint, increase the system parameter 'Interpolation Buffer Startup Adjust' in topic Motion and type Motion Planner.
- - The warning can be suppressed using the RAPID instruction CornerPathWarning.
Frequently asked · Questions fréquentes
- What does ABB error 50124 mean?
- ABB 50124 (“Zone converted to fine point”): Zone converted to fine point — ABB robot hardware event on the Zone converted to fine point (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 50124?
- Inspect the Zone converted to fine point, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →