ABB Error 50369Calibration using stored offset failed

Error / Erreur

🇫🇷 Calibration using stored offset failed

ABB — CATALOGUE PRODUCTION

ABB 50369 (“Calibration using stored offset failed”): Calibration using stored offset failed — ABB robot hardware event on the calibration using stored offset failed (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Calibration using stored offset failed — ABB robot hardware event on the calibration using stored offset failed (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

Failed to calibrate the sensor using stored offset. The force control system is not calibrated. It is not possible to activate force control. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the calibration using stored offset failed, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : Calibration using stored offset is only possible if a normal calibration has been performed earlier.

Frequently asked · Questions fréquentes

What does ABB error 50369 mean?
ABB 50369 (“Calibration using stored offset failed”): Calibration using stored offset failed — ABB robot hardware event on the calibration using stored offset failed (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 50369?
Inspect the calibration using stored offset failed, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →