LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 50394The Path for the Unit is cleared

Error / Erreur

🇫🇷 The Path for the Unit is cleared

ABB — CATALOGUE PRODUCTION

ABB 50394 (“The Path for the Unit is cleared”): The Path for the Unit is cleared — ABB robot hardware event on the The Path for the Unit is cleared (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

The Path for the Unit is cleared — ABB robot hardware event on the The Path for the Unit is cleared (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

The robot arg is semi coordinated to unit arg from another task and the path for the unit has been cleared. This can happen after a modpos, SyncMoveOff, SyncMoveSuspend, ActUnit, DeactUnit, ClearPath or if the unit has no move instruction with a well-defined position before starting the semi coordinated movement. The position of unit arg cannot be read from other tasks. Program run or restart will be interrupted. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the The Path for the Unit is cleared, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • If the programmed position of the unit is moved by modpos when the robot is semi coordinated to the unit, then step the unit to the new position to define the path and move the program pointer in the robot program to be able to restart the program.
  • Make sure that the unit has a move instruction with a finepoint to a well-defined position and that all programs has a WaitSyncTask before and after the semi coordinated movement.
  • Make sure that the unit is not moved during the semi coordinated movement.
  • Note that WaitSyncTask also is needed after the semi coordination, before SyncMoveOn and SyncMoveResume.
  • 4.7 5 xxxx

Frequently asked · Questions fréquentes

What does ABB error 50394 mean?
ABB 50394 (“The Path for the Unit is cleared”): The Path for the Unit is cleared — ABB robot hardware event on the The Path for the Unit is cleared (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 50394?
Inspect the The Path for the Unit is cleared, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →