ABB Error 50413 — Bleeder resistor overload error
Error / Erreur🇫🇷 Bleeder resistor overload error
ABB — CATALOGUE PRODUCTION
ABB 50413 (“Bleeder resistor overload error”): Bleeder resistor overload error — ABB robot hardware event on the bleeder resistor resistor overload error (IRC5).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Bleeder resistor overload error — ABB robot hardware event on the bleeder resistor resistor overload error (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
In drive module arg , the bleeder resistor connected to the rectifier unit at drive unit position arg was overloaded. No operation will be possible until the bleeder resistor has cooled down. The system goes to Motors Off. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.
What to check · Que vérifier
- Inspect the bleeder resistor resistor overload error, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- probable : - 1 The user program may contain too much deceleration of the manipulator's axes.
- This fault is more likely if the system contains additional axes.
- - 2 The bleeder resistor has wrong resistance.
- - 3 Short circuit in motor cable between phase to phase or phase to ground.
- Rewrite the user program to reduce the amount of high decelerations.
Frequently asked · Questions fréquentes
- What does ABB error 50413 mean?
- ABB 50413 (“Bleeder resistor overload error”): Bleeder resistor overload error — ABB robot hardware event on the bleeder resistor resistor overload error (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 50413?
- Inspect the bleeder resistor resistor overload error, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →