LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 50429CSS parameter damping obsolete

Error / Erreur

🇫🇷 CSS parameter damping obsolete

ABB — CATALOGUE PRODUCTION

ABB 50429 (“CSS parameter damping obsolete”): CSS parameter damping obsolete — ABB robot hardware event on the CSS parameter damping obsolete (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

CSS parameter damping obsolete — ABB robot hardware event on the CSS parameter damping obsolete (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

The CSS parameters regarding damping is obsolete. The damping is now in all directions set by the stiffness to damping ratio. To change the behavior of the non soft directions, use the parameters 'Stiffness in non soft dir'. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the CSS parameter damping obsolete, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Change the damping parameters to 'Stiffness in non soft dir' according to description in the manual.

Frequently asked · Questions fréquentes

What does ABB error 50429 mean?
ABB 50429 (“CSS parameter damping obsolete”): CSS parameter damping obsolete — ABB robot hardware event on the CSS parameter damping obsolete (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 50429?
Inspect the CSS parameter damping obsolete, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →