LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 50484Stop-point too far away from circle

Error / Erreur

🇫🇷 Stop-point too far away from circle

ABB — CATALOGUE PRODUCTION

ABB 50484 (“Stop-point too far away from circle”): Stop-point too far away from circle — ABB robot hardware event on the Stop-point too far away from circle (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Stop-point too far away from circle — ABB robot hardware event on the Stop-point too far away from circle (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

Task: arg Program ref. arg The detected stop-point during execution of a SearchC instruction is too far away from the circle-arc. This can happen if a large zone is used in the preceding movement-instruction. It will not be possible to run the movement backwards. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Stop-point too far away from circle, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : A too large zone was used in the movement-instruction preceding the SearchC.
  • Use a smaller zone in the movement-instruction preceding the SearchC.

Frequently asked · Questions fréquentes

What does ABB error 50484 mean?
ABB 50484 (“Stop-point too far away from circle”): Stop-point too far away from circle — ABB robot hardware event on the Stop-point too far away from circle (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 50484?
Inspect the Stop-point too far away from circle, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →