ABB Error 50505Spot Gun configuration warning

Error / Erreur

🇫🇷 Spot Gun configuration warning

ABB — CATALOGUE PRODUCTION

ABB 50505 (“Spot Gun configuration warning”): Spot Gun configuration warning — ABB robot hardware event on the Spot Gun configuration warning (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Spot Gun configuration warning — ABB robot hardware event on the Spot Gun configuration warning (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

The value set in distance for missing tip check is smaller than how far motor will move during max force squeeze. This could cause false errors of the missing tip check for joint arg . Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Spot Gun configuration warning, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Increase the distance for missing tip check or reduce max gun force.

Frequently asked · Questions fréquentes

What does ABB error 50505 mean?
ABB 50505 (“Spot Gun configuration warning”): Spot Gun configuration warning — ABB robot hardware event on the Spot Gun configuration warning (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 50505?
Inspect the Spot Gun configuration warning, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →