ABB Error 71016 — Trop de sorties logiques
Error / Erreur🇫🇷 Trop de sorties logiques
ABB — CATALOGUE PRODUCTION
ABB 71016 (“Trop de sorties logiques”): Trop de sorties logiques — ABB robot hardware event on the controller hardware (IRC5). Likely part: DSQC 350 (DeviceNet digital I/O module).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Trop de sorties logiques — ABB robot hardware event on the controller hardware (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
This code's manufacturer text exists only in French in the ABB manuals it comes from. It is reproduced verbatim above; your robot's own manual remains authoritative. Analyse\Cause: - Le nombre de sorties pour la carte … est plus grand que … Traitement: 1. Réduire le nombre de sorties 2. Pour les DSQC 350,351 et 352 deux reboots sont nécessaires 3. Redémarrer la baie (sectionneur)
What to check · Que vérifier
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
Part to check / replace · Pièce à contrôler / remplacer
ABB 71016 points to the hardware below — start here before ordering. · 71016 met en cause l'organe ci-dessous : commencez par là.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.
Frequently asked · Questions fréquentes
- What does ABB error 71016 mean?
- ABB 71016 (“Trop de sorties logiques”): Trop de sorties logiques — ABB robot hardware event on the controller hardware (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 71016?
- Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
- Which part is involved in ABB 71016?
- 71016 points to DSQC 350 (DeviceNet digital I/O module). Confirm the real cause against the robot backup before replacing a part.
Related codes / Codes liés
Same hardware involved / Même matériel en cause
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →