LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 71022Max physique trop grand

Error / Erreur

🇫🇷 Max physique trop grand

ABB — CATALOGUE PRODUCTION

ABB 71022 (“Max physique trop grand”): Max physique trop grand — ABB robot hardware event on the Max physique trop grand (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Max physique trop grand — ABB robot hardware event on the Max physique trop grand (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

This code's manufacturer text exists only in French in the ABB manuals it comes from. It is reproduced verbatim above; your robot's own manual remains authoritative. Analyse\Cause: - Config du Signal: … - Valeur Max Physique trop grande. Elle doit être < …

What to check · Que vérifier

  • Inspect the Max physique trop grand, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Changer cette valeur en configuration71023: Min physique trop petit Analyse\Cause: - Config du Signal: … - Valeur Min Physique trop faible.
  • Elle doit être > … Traitement: 1.
  • Changer cette valeur en configuration

Frequently asked · Questions fréquentes

What does ABB error 71022 mean?
ABB 71022 (“Max physique trop grand”): Max physique trop grand — ABB robot hardware event on the Max physique trop grand (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 71022?
Inspect the Max physique trop grand, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →