LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 71171Unité E/S invalide

Error / Erreur

🇫🇷 Unité E/S invalide

ABB — CATALOGUE PRODUCTION

ABB 71171 (“Unité E/S invalide”): Unité E/S invalide — ABB robot hardware event on the controller hardware (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Unité E/S invalide — ABB robot hardware event on the controller hardware (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

This code's manufacturer text exists only in French in the ABB manuals it comes from. It is reproduced verbatim above; your robot's own manual remains authoritative. Analyse\Cause: - Le type d'unité … utilisé par l'unité … n'est pas de fourniture ABB

What to check · Que vérifier

  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • S'assurer que l'option I/O Plus est installée Analyse\Cause: - La durée du chien de garde de l'unité … doit être > max des min\_slave\_interval = ….
  • Traitement: 1.
  • Augmenter la durée du chien de garde

Frequently asked · Questions fréquentes

What does ABB error 71171 mean?
ABB 71171 (“Unité E/S invalide”): Unité E/S invalide — ABB robot hardware event on the controller hardware (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 71171?
Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault. S'assurer que l'option I/O Plus est installée Analyse\Cause: - La durée du chien de garde de l'unité … doit être > max des min\_slave\_interval = ….

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →