LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 71313Device command order number not unique

Error / Erreur

🇫🇷 Device command order number not unique

ABB — CATALOGUE PRODUCTION

ABB 71313 (“Device command order number not unique”): Device command order number not unique — ABB robot hardware event on the Device command order number not unique (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Device command order number not unique — ABB robot hardware event on the Device command order number not unique (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

The I/O configuration is invalid. The device command <arg> connected to the I/O device <arg> has the same order number <arg> as the device command <arg>. The order number of device commands connected to the same I/O device must be unique. This device command has been rejected. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Device command order number not unique, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Modify the I/O configuration so that device commands on the same I/O device have unique order numbers.

Frequently asked · Questions fréquentes

What does ABB error 71313 mean?
ABB 71313 (“Device command order number not unique”): Device command order number not unique — ABB robot hardware event on the Device command order number not unique (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 71313?
Inspect the Device command order number not unique, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →