LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 71349Invalid signal size

Error / Erreur

🇫🇷 Invalid signal size

ABB — CATALOGUE PRODUCTION

ABB 71349 (“Invalid signal size”): Invalid signal size — ABB robot hardware event on the Invalid signal size (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Invalid signal size — ABB robot hardware event on the Invalid signal size (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

The I/O configuration for I/O signal arg is invalid. There is a mismatch between the signal type and the size of the signal. The signal size arg is given by the device map: arg . This I/O signal has been rejected. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Invalid signal size, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Correct either the signal type or the device map so that the following rules are fulfilled: - The size of digital I/O signals must be exactly one bit.
  • - The size of analog and group I/O signals must be between 1 and 32 bits.

Frequently asked · Questions fréquentes

What does ABB error 71349 mean?
ABB 71349 (“Invalid signal size”): Invalid signal size — ABB robot hardware event on the Invalid signal size (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 71349?
Inspect the Invalid signal size, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →