ABB Error 71362 — I/O signal mapped outside the I/O device data area

Error

ABB 71362 (“I/O signal mapped outside the I/O device data area”): I/O signal mapped outside the I/O device data area: an I/O signal is mapped beyond the data area declared for the unit. Likely part: Unité d'E/S / Mappage de signal (Unité d'E/S / Mappage de signal).

Updated 2026-10-22 · LogrobotLM reference

What it means

I/O signal mapped outside the I/O device data area: an I/O signal is mapped beyond the data area declared for the unit. Encountered on fieldbus modules (PROFINET IO, EtherNet/IP, DeviceNet).

What to check

  • Compare the size of the data area declared for the unit (Connection Input/Output Size parameters) with the actual signal mapping.
  • Correct the address of the out-of-range signal or increase the declared size.
  • Check that the configuration file actually matches the physically installed module.
  • Note: Configuration error, not a component error, but it appears as a block at the end of the Elog at start-up and often masks the real I/O hardware errors (71367, 71424).