ABB Error 71414 — Concurrent changes of signal value
Error / Erreur🇫🇷 Concurrent changes of signal value
ABB — CATALOGUE PRODUCTION
ABB 71414 (“Concurrent changes of signal value”): Concurrent changes of signal value — ABB robot hardware event on the Concurrent changes of signal value (IRC5).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Concurrent changes of signal value — ABB robot hardware event on the Concurrent changes of signal value (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
Concurrent changes of I/O signal arg value have been detected. A signal value change of I/O signal arg is aborted due to another value change of the same I/O signal. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.
What to check · Que vérifier
- Inspect the Concurrent changes of signal value, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- probable : The concurrent value change is due to an undesired signal change sequence in a program.
- Multiple changes of I/O signal arg might appear when a I/O signal is pulsed, e.g.
- SetDO arg , 0; PulseDO /High /PLength = 0.01, arg; WaitTime 0.01; SetDO arg , 1; The I/O signal arg will be 1 at the end, but at rare occasions there will not be any visible pulse.
- This type of sequence should be avoided.
- Verify that concurrent value changes are desired of I/O signal arg , otherwise modify the signal change sequence.
Frequently asked · Questions fréquentes
- What does ABB error 71414 mean?
- ABB 71414 (“Concurrent changes of signal value”): Concurrent changes of signal value — ABB robot hardware event on the Concurrent changes of signal value (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 71414?
- Inspect the Concurrent changes of signal value, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →