ABB Error 71424 — DeviceNet Lean bus off
Error / Erreur🇫🇷 Bus DeviceNet Lean / Câblage
E/S & BUS DE TERRAIN (71xxx, 41555)
ABB 71424 (“DeviceNet Lean bus off”): DeviceNet Lean bus off — ABB robot hardware event on the Bus DeviceNet Lean / Câblage (IRC5). Likely part: Bus DeviceNet Lean / Câblage (Bus DeviceNet Lean / Câblage).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
DeviceNet Lean bus off — ABB robot hardware event on the Bus DeviceNet Lean / Câblage (IRC5). Specific to this controller generation. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.
DeviceNet Lean bus off : le contrôleur de bus est passé à l'état bus off à cause d'un taux d'erreurs de trame excessif. Toute communication sur le bus est interrompue.
What to check · Que vérifier
- Inspect the Bus DeviceNet Lean / Câblage, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- Vérifier l'alimentation du bus et les deux résistances de terminaison.
- Contrôler la qualité du câble, des dérivations et le respect de la longueur maximale.
- Rechercher une unité fautive en déconnectant les nœuds un par un.
- Redémarrer la baie après correction.
- À savoir : Symptôme réseau global : se déclenche en cascade avec plusieurs 71367.
Part to check / replace · Pièce à contrôler / remplacer
ABB 71424 points to the hardware below — start here before ordering. · 71424 met en cause l'organe ci-dessous : commencez par là.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.
Frequently asked · Questions fréquentes
- What does ABB error 71424 mean?
- ABB 71424 (“DeviceNet Lean bus off”): DeviceNet Lean bus off — ABB robot hardware event on the Bus DeviceNet Lean / Câblage (IRC5). Specific to this controller generation. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 71424?
- Inspect the Bus DeviceNet Lean / Câblage, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
- Which part is involved in ABB 71424?
- 71424 points to Bus DeviceNet Lean / Câblage (Bus DeviceNet Lean / Câblage). Confirm the real cause against the robot backup before replacing a part.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →