ABB Error 71424 — DeviceNet Lean bus off
ErrorABB 71424 (“DeviceNet Lean bus off”): DeviceNet Lean bus off: the bus controller has entered the bus off state due to an excessive frame error rate. Likely part: Bus DeviceNet Lean / Câblage (Bus DeviceNet Lean / Câblage).
Updated 2026-10-22 · LogrobotLM reference
What it means
DeviceNet Lean bus off: the bus controller has entered the bus off state due to an excessive frame error rate. All communication on the bus is interrupted.
What to check
- Check the bus power supply and both termination resistors.
- Check the quality of the cable and drop lines, and that the maximum length is respected.
- Look for a faulty unit by disconnecting the nodes one by one.
- Restart the cabinet after correction.
- Note: Global network symptom: triggers in a cascade with several 71367.
Part to check / replace
ABB 71424 points to the hardware below — start here before ordering.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.
Related codes