LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 71499I/O signals in cross connection has overlapping device map

Error / Erreur

🇫🇷 I/O signals in cross connection has overlapping device map

ABB — CATALOGUE PRODUCTION

ABB 71499 (“I/O signals in cross connection has overlapping device map”): I/O signals in cross connection has overlapping device map — ABB robot hardware event on the I/O signals in cross connection has overlapping device map (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

I/O signals in cross connection has overlapping device map — ABB robot hardware event on the I/O signals in cross connection has overlapping device map (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

The I/O configuration of cross connection arg is invalid. The resultant I/O signal arg has an overlapping device map with the inverted actor I/O signal arg . Using I/O signals with overlapping device map in a cross connection can cause infinity signal setting loops. The cross connection has been rejected, and no functions depending on it will work. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the I/O signals in cross connection has overlapping device map, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Correct the device map or define one of the I/O signals as simulated.

Frequently asked · Questions fréquentes

What does ABB error 71499 mean?
ABB 71499 (“I/O signals in cross connection has overlapping device map”): I/O signals in cross connection has overlapping device map — ABB robot hardware event on the I/O signals in cross connection has overlapping device map (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below…
How do you troubleshoot ABB error 71499?
Inspect the I/O signals in cross connection has overlapping device map, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →