LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 71552Max number of device trust levels exceeded

Error / Erreur

🇫🇷 Max number of device trust levels exceeded

ABB — CATALOGUE PRODUCTION

ABB 71552 (“Max number of device trust levels exceeded”): Max number of device trust levels exceeded — ABB robot hardware event on the Max number of device trust levels exceeded (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Max number of device trust levels exceeded — ABB robot hardware event on the Max number of device trust levels exceeded (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

The I/O configuration is invalid. The maximum number, arg , of device trust levels in the I/O system has been exceeded. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Max number of device trust levels exceeded, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Modify the configuration of the I/O system (by reducing the number of device trust levels) so that the maximum limit is not exceeded.

Frequently asked · Questions fréquentes

What does ABB error 71552 mean?
ABB 71552 (“Max number of device trust levels exceeded”): Max number of device trust levels exceeded — ABB robot hardware event on the Max number of device trust levels exceeded (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains…
How do you troubleshoot ABB error 71552?
Inspect the Max number of device trust levels exceeded, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →