ABB Error 71591 — Input signal update rate too high
Error / Erreur🇫🇷 Input signal update rate too high
ABB — CATALOGUE PRODUCTION
ABB 71591 (“Input signal update rate too high”): Input signal update rate too high — ABB robot hardware event on the Input signal update rate too high (IRC5).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Input signal update rate too high — ABB robot hardware event on the Input signal update rate too high (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
Device arg is producing input signal changes at too high rate. Possible loss of signal changes. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.
What to check · Que vérifier
- Inspect the Input signal update rate too high, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- Configure device to produce input changes at a lower rate by changing to a higher 'Input Request Packet Interval' value or change 'Connection Timeout Multiplier' to a higher value.
- If this is the internal device change the corresponding parameters at the Scanner.
Frequently asked · Questions fréquentes
- What does ABB error 71591 mean?
- ABB 71591 (“Input signal update rate too high”): Input signal update rate too high — ABB robot hardware event on the Input signal update rate too high (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 71591?
- Inspect the Input signal update rate too high, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →