LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 90226General Stop conflict

Error / Erreur

🇫🇷 General Stop conflict

ABB — CATALOGUE PRODUCTION

ABB 90226 (“General Stop conflict”): General Stop conflict — ABB robot hardware event on the General Stop conflict (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

General Stop conflict — ABB robot hardware event on the General Stop conflict (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

Only one of the two General Mode Safeguarded Stop chains was opened. The system goes to status SYS HALT. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the General Stop conflict, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : Any of the switches connected to the General Stop chain may be faulty or not correctly connected, causing only one channel to close.
  • The General Stop chain is described in the Trouble Shooting Manual, IRC5.
  • Check cables and connections.
  • Check other event messages occurring at the same time to determine which switch caused the fault.
  • Make sure all switches are working correctly.

Frequently asked · Questions fréquentes

What does ABB error 90226 mean?
ABB 90226 (“General Stop conflict”): General Stop conflict — ABB robot hardware event on the General Stop conflict (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 90226?
Inspect the General Stop conflict, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →