LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 90232Delayed Auto Stop due to circuit imbalance

Error / Erreur

🇫🇷 Delayed Auto Stop due to circuit imbalance

ABB — CATALOGUE PRODUCTION

ABB 90232 (“Delayed Auto Stop due to circuit imbalance”): Delayed Auto Stop due to circuit imbalance — ABB robot hardware event on the Delayed Auto Stop due to circuit imbalance (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Delayed Auto Stop due to circuit imbalance — ABB robot hardware event on the Delayed Auto Stop due to circuit imbalance (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

The system has detected an imbalance in the two parallel Auto Stop circuits. The system goes to status Guard Stop after approximately 1 sec. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Delayed Auto Stop due to circuit imbalance, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : The contact pair in any of the safety devices connected to the Auto Stop circuit is not working correctly.
  • Isolate the safety device causing the conflict.
  • Make sure the device used is a two-channel device.
  • Check the contact pair.
  • Make sure all connections are tight.

Frequently asked · Questions fréquentes

What does ABB error 90232 mean?
ABB 90232 (“Delayed Auto Stop due to circuit imbalance”): Delayed Auto Stop due to circuit imbalance — ABB robot hardware event on the Delayed Auto Stop due to circuit imbalance (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains…
How do you troubleshoot ABB error 90232?
Inspect the Delayed Auto Stop due to circuit imbalance, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →