ABB Error 90306Not possible to activate I/O signals in Safety system

Error / Erreur

🇫🇷 Not possible to activate I/O signals in Safety system

ABB — CATALOGUE PRODUCTION

ABB 90306 (“Not possible to activate I/O signals in Safety system”): Not possible to activate I/O signals in Safety system — ABB robot hardware event on the Not possible to activate I/O signals in Safety system (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Not possible to activate I/O signals in Safety system — ABB robot hardware event on the Not possible to activate I/O signals in Safety system (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

It was not possible to activate I/O signals in the safety system during startup. The safety system cannot use I/O signals to detect state changes and critical states. This will end up in a system failure condition. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Not possible to activate I/O signals in Safety system, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : Drive system option is not present.
  • Check if there is a drive system option present.
  • Create a new system including the correct drive system option and do a restart.

Frequently asked · Questions fréquentes

What does ABB error 90306 mean?
ABB 90306 (“Not possible to activate I/O signals in Safety system”): Not possible to activate I/O signals in Safety system — ABB robot hardware event on the Not possible to activate I/O signals in Safety system (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your…
How do you troubleshoot ABB error 90306?
Inspect the Not possible to activate I/O signals in Safety system, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →