ABB Error 90313 — Enable 1 supervision fault
Error / Erreur🇫🇷 Enable 1 supervision fault
ABB — CATALOGUE PRODUCTION
ABB 90313 (“Enable 1 supervision fault”): Enable 1 supervision fault — ABB robot hardware event on the Enable 1 supervision fault (IRC5).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Enable 1 supervision fault — ABB robot hardware event on the Enable 1 supervision fault (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
The Enable 1 circuit has been broken. This circuit monitors the function of the safety system and the main computer. The system goes to status SYS HALT. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.
What to check · Que vérifier
- Inspect the Enable 1 supervision fault, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- probable : A fault, probably a software fault, has been detected by any of the units supervised by the Enable 1 circuit.
- Attempt restarting by pressing the Motors ON button.
- If restarting is IMPOSSIBLE it indicates a possible hardware fault.
- If restarting is POSSIBLE, it indicates a software fault.
- In such case, contact your local ABB representative.
Frequently asked · Questions fréquentes
- What does ABB error 90313 mean?
- ABB 90313 (“Enable 1 supervision fault”): Enable 1 supervision fault — ABB robot hardware event on the Enable 1 supervision fault (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 90313?
- Inspect the Enable 1 supervision fault, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →