LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 90464SC arg OSR Limit exceeded

Error / Erreur

🇫🇷 SC arg OSR Limit exceeded

ABB — CATALOGUE PRODUCTION

ABB 90464 (“SC arg OSR Limit exceeded”): SC arg OSR Limit exceeded — ABB robot hardware event on the SC arg OSR Limit exceeded (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

SC arg OSR Limit exceeded — ABB robot hardware event on the SC arg OSR Limit exceeded (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

Safety Controller (SC) arg detected a too big difference between the ordered and actual position inside Operational Safety Range (OSR), for mechanical unit arg on axis arg . Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the SC arg OSR Limit exceeded, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • - Check for collision.
  • - Check that Operational Safety Range (OSR) Tolerance in the safety configuration is not set too low.
  • - Synchronize the Safety Controller, if the revolution counters have been updated since last synchronization.

Frequently asked · Questions fréquentes

What does ABB error 90464 mean?
ABB 90464 (“SC arg OSR Limit exceeded”): SC arg OSR Limit exceeded — ABB robot hardware event on the SC arg OSR Limit exceeded (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 90464?
Inspect the SC arg OSR Limit exceeded, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →