LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 90515Safety Controller Tool Speed violation

Error / Erreur

🇫🇷 Safety Controller Tool Speed violation

ABB — CATALOGUE PRODUCTION

ABB 90515 (“Safety Controller Tool Speed violation”): Safety Controller Tool Speed violation — ABB robot hardware event on the Safety Controller Tool Speed violation (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Safety Controller Tool Speed violation — ABB robot hardware event on the Safety Controller Tool Speed violation (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

Tool Speed supervision arg was violated in the safety controller for drive module arg . The cause was arg . If configured with a stop action, the safety controller will stop all robot movements. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Safety Controller Tool Speed violation, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : - 1 TCP speed too high.
  • - 2 Elbow speed too high.
  • - 3 Tool speed at point 1 too high.
  • - 4 Tool speed at point 2 too high.
  • - 5 Tool speed at point 3 too high.

Frequently asked · Questions fréquentes

What does ABB error 90515 mean?
ABB 90515 (“Safety Controller Tool Speed violation”): Safety Controller Tool Speed violation — ABB robot hardware event on the Safety Controller Tool Speed violation (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 90515?
Inspect the Safety Controller Tool Speed violation, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →