LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 90666Safety Controller configuration version not supported

Error / Erreur

🇫🇷 Safety Controller configuration version not supported

ABB — CATALOGUE PRODUCTION

ABB 90666 (“Safety Controller configuration version not supported”): Safety Controller configuration version not supported — ABB robot hardware event on the Safety Controller configuration version not supported (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Safety Controller configuration version not supported — ABB robot hardware event on the Safety Controller configuration version not supported (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

The safety controller configuration version is not supported by the software in the safety controller. The system will stop all robot movements. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Safety Controller configuration version not supported, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : - 1 The safety controller configuration version is too new.
  • - 2 The safety controller software is too old.
  • Downgrade the safety controller configuration version.
  • Upgrade the safety controller software.

Frequently asked · Questions fréquentes

What does ABB error 90666 mean?
ABB 90666 (“Safety Controller configuration version not supported”): Safety Controller configuration version not supported — ABB robot hardware event on the Safety Controller configuration version not supported (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your…
How do you troubleshoot ABB error 90666?
Inspect the Safety Controller configuration version not supported, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →