LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 90832File arg not found

Error / Erreur

🇫🇷 File arg not found

ABB — CATALOGUE PRODUCTION

ABB 90832 (“File arg not found”): File arg not found — ABB robot hardware event on the File arg not found (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

File arg not found — ABB robot hardware event on the File arg not found (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

The XML file arg , which is used by the safety controller, was not found. No operation will be possible until the fault has been corrected and the system has been restarted. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the File arg not found, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : - 1 Restore of a backup from a system with a different configuration.
  • - 2 Disc corruption.
  • Restore to a system with the correct configuration.
  • Reinstall system.

Frequently asked · Questions fréquentes

What does ABB error 90832 mean?
ABB 90832 (“File arg not found”): File arg not found — ABB robot hardware event on the File arg not found (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 90832?
Inspect the File arg not found, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →