LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm APSH-048 — WARN PLC comm error - invert check

FANUC APSH-048 (“WARN PLC comm error - invert check”): The backup style group is not the 1's complement (inverse) of the style input group. First check: Verify that the PLC is sending the correct invert style to the correct group.

Updated 2026-09-17 · LogrobotLM reference

Description

The backup style group is not the 1's complement (inverse) of the style input group.

Remedy

Verify that the PLC is sending the correct invert style to the correct group. Disable invert checking in the PNS Cell Setup menu.

Related codes