FANUC Alarm APSH-048 — WARN PLC comm error - invert check
FANUC APSH-048 (“WARN PLC comm error - invert check”): The backup style group is not the 1's complement (inverse) of the style input group. First check: Verify that the PLC is sending the correct invert style to the correct group.
Updated 2026-08-29 · LogrobotLM reference
Description
The backup style group is not the 1's complement (inverse) of the style input group.
Remedy · Remède
Verify that the PLC is sending the correct invert style to the correct group. Disable invert checking in the PNS Cell Setup menu.
Frequently asked · Questions fréquentes
- What does FANUC alarm APSH-048 mean?
- FANUC APSH-048 (“WARN PLC comm error - invert check”): The backup style group is not the 1's complement (inverse) of the style input group.
- How do you troubleshoot FANUC alarm APSH-048?
- Verify that the PLC is sending the correct invert style to the correct group. Disable invert checking in the PNS Cell Setup menu.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →