LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm CVIS-033 — The operation has timed out.

FANUC CVIS-033 (“The operation has timed out.”): The system could not find the object within the time limit. First check: In the Geometric Pattern Match (GPM) Tool Setup screen, check if you have the Orientation, Scale, or Aspect Ratio degrees of freedom enabled.

Updated 2026-09-17 · LogrobotLM reference

Description

The system could not find the object within the time limit.

Remedy

In the Geometric Pattern Match (GPM) Tool Setup screen, check if you have the Orientation, Scale, or Aspect Ratio degrees of freedom enabled. If so, reduce the maximums and/or increase the minimums and try to find again. If it still fails, disable one or more degrees of freedom. Increase the allowable processing time. Alternatively, make one of the following adjustments so as to decrease the required processing time.

Related codes