FANUC Alarm CVIS-033 — The operation has timed out.
FANUC CVIS-033 (“The operation has timed out.”): The system could not find the object within the time limit. First check: In the Geometric Pattern Match (GPM) Tool Setup screen, check if you have the Orientation, Scale, or Aspect Ratio degrees of freedom enabled.
Updated 2026-09-17 · LogrobotLM reference
Description
The system could not find the object within the time limit.
Remedy
In the Geometric Pattern Match (GPM) Tool Setup screen, check if you have the Orientation, Scale, or Aspect Ratio degrees of freedom enabled. If so, reduce the maximums and/or increase the minimums and try to find again. If it still fails, disable one or more degrees of freedom. Increase the allowable processing time. Alternatively, make one of the following adjustments so as to decrease the required processing time.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →