LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm CVIS-037 — The model pattern is not symmetrical.

FANUC CVIS-037 (“The model pattern is not symmetrical.”): For a non-rotatable model, an attempt was made to have the model origin automatically set by clicking the Center Origin button. First check: The model origin of a non-rotatable model cannot be set automatically by clicking the Center Origin button.

Updated 2026-09-17 · LogrobotLM reference

Description

For a non-rotatable model, an attempt was made to have the model origin automatically set by clicking the Center Origin button.

Remedy

The model origin of a non-rotatable model cannot be set automatically by clicking the Center Origin button. Use the Set Origin button to set the model origin.

Related codes