FANUC Alarm CVIS-037The model pattern is not symmetrical.

FANUC CVIS-037 (“The model pattern is not symmetrical.”): For a non-rotatable model, an attempt was made to have the model origin automatically set by clicking the Center Origin button. First check: The model origin of a non-rotatable model cannot be set automatically by clicking the Center Origin button.

Updated 2026-08-29 · LogrobotLM reference

Description

For a non-rotatable model, an attempt was made to have the model origin automatically set by clicking the Center Origin button.

Remedy · Remède

The model origin of a non-rotatable model cannot be set automatically by clicking the Center Origin button. Use the Set Origin button to set the model origin.

Frequently asked · Questions fréquentes

What does FANUC alarm CVIS-037 mean?
FANUC CVIS-037 (“The model pattern is not symmetrical.”): For a non-rotatable model, an attempt was made to have the model origin automatically set by clicking the Center Origin button.
How do you troubleshoot FANUC alarm CVIS-037?
The model origin of a non-rotatable model cannot be set automatically by clicking the Center Origin button. Use the Set Origin button to set the model origin.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →