FANUC Alarm CVIS-037 — The model pattern is not symmetrical.
Description
For a non-rotatable model, an attempt was made to have the model origin automatically set by clicking the Center Origin button.
Remedy · Remède
The model origin of a non-rotatable model cannot be set automatically by clicking the Center Origin button. Use the Set Origin button to set the model origin.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.